2.
Rev. bras. oftalmol ; 81: e0041, 2022. tab, graf
Article in English | LILACS | ID: biblio-1387975

ABSTRACT

ABSTRACT Glaucoma drainage devices are important therapeutic options for cases of refractory glaucoma, in which trabeculectomy with antimetabolites has shown high risk of failure. There are devices with different sizes, designs and materials, and several studies have been conducted to test their safety and effectiveness. Despite known complications, their use has progressively increased in recent years, and they are the primary surgical option, in some situations. The aim of this review is to discuss the importance, mechanisms, biomaterials, results and complications of glaucoma drainage devices.


RESUMO Os dispositivos de drenagem para glaucoma são importante opção terapêutica em casos de glaucomas refratários, nos quais a trabeculectomia com antimetabólitos tem alta chance de falência. Há dispositivos com diferentes tamanhos, desenhos e materiais, e muitos estudos foram realizados para testar sua segurança e eficácia. Apesar de suas conhecidas complicações, seu uso tem aumentado progressivamente nos últimos anos, inclusive como primeira opção cirúrgica, em algumas situações. O objetivo desta revisão foi discutir a importância, os mecanismos, os biomateriais, os resultados e as complicações dos dispositivos de drenagem para glaucoma.


Subject(s)
Humans , Glaucoma/surgery , Filtering Surgery/instrumentation , Glaucoma Drainage Implants , Biocompatible Materials , Glaucoma/physiopathology , Filtering Surgery/methods , Prosthesis Implantation , Intraocular Pressure/physiology
3.
Rev. bras. oftalmol ; 81: e0036, 2022. tab, graf
Article in English | LILACS | ID: biblio-1376779

ABSTRACT

ABSTRACT The purpose of this study was to highlight the impact of biomechanical corneal response in available in vivo tonometry methods for glaucoma management. Systematic review of non-contact air-puff tonometers that analyzes the corneal deformation response, with special focus on the investigation of the correlation of derived parameters with intraocular pressure measurements. The two actual and commercially available in vivo corneal tonometers provide promising information about biomechanical characteristics of the cornea and its relation to glaucoma, allowing the development of new protocols to evaluate, diagnose, and manage this disease.


RESUMO O objetivo deste estudo é destacar o impacto da resposta biomecânica corneana em métodos de tonometria in vivo disponíveis para o manejo do glaucoma. Trata-se de revisão sistemática de tonômetros de ar que analisa a resposta à deformação corneana, com foco especial na investigação da correlação dos parâmetros derivados com as medições da pressão intraocular. Os dois tonômetros mais recentes e comercialmente disponíveis fornecem informações promissoras sobre as características biomecânicas da córnea e sua relação com o glaucoma, permitindo o desenvolvimento de novos protocolos para avaliar, diagnosticar e controlar a doença.


Subject(s)
Humans , Tonometry, Ocular/instrumentation , Tonometry, Ocular/methods , Biomechanical Phenomena , Cornea/anatomy & histology , Cornea/physiology , Intraocular Pressure/physiology , Glaucoma/physiopathology , Ocular Hypertension/physiopathology , Diagnostic Techniques, Ophthalmological/instrumentation , Elasticity/physiology , Models, Theoretical
4.
Rev. bras. oftalmol ; 81: e0102, 2022. tab, graf
Article in English | LILACS | ID: biblio-1407671

ABSTRACT

ABSTRACT The rate of visual field progression is an essential factor in determining risk of visual disability or blindness in glaucoma patients. Knowledge of the rate of progression of a particular patient, in combination with an estimation of their longevity and other clinical factors, allows clinicians to optimize management by providing appropriately aggressive treatment. Despite decades of research on the treatment of glaucoma, the natural history of glaucomatous visual field progression in untreated and treated patients remains unclear. The purpose of this review is to provide a comprehensive summary of the literature surrounding the rate of visual field progression in glaucoma. Most of the available data pertains to primary open angle glaucoma, but we will also review progression rates in other subtypes of open angle glaucoma, such as pseudoexfoliative glaucoma and normal tension glaucoma, as well as in primary angle closure glaucoma. Specifically, we will cover methods to identify rates of progression, rates of progression in treated versus untreated patients, factors that may influence progression, and lastly, suggest some parameters that might help clinicians in determining acceptable rates of visual field deterioration in patients with glaucoma.


RESUMO A taxa de progressão do campo visual é um fator essencial para determinar o risco de incapacidade visual ou cegueira em pacientes com glaucoma. Conhecer a taxa de progressão de um determinado paciente, em combinação com uma estimativa de sua longevidade e outros fatores clínicos, permite que os médicos otimizem a conduta, fornecendo um tratamento adequadamente agressivo. Apesar de décadas de pesquisa sobre o tratamento do glaucoma, a história natural da progressão do campo visual glaucomatoso em pacientes não tratados e tratados permanece pouco clara. O objetivo desta revisão é fornecer um resumo abrangente da literatura sobre a taxa de progressão do campo visual do glaucoma. A maioria dos dados disponíveis diz respeito ao glaucoma de ângulo aberto primário, mas também revisaremos as taxas de progressão em outros subtipos de glaucoma de ângulo aberto, como o glaucoma pseudoexfoliativo e o glaucoma de tensão normal, bem como o glaucoma primário de ângulo fechado. Especificamente, iremos cobrir métodos para identificar taxas de progressão, taxas de progressão em pacientes tratados versus não tratados, fatores que podem influenciar a progressão e, finalmente, sugerir alguns parâmetros que podem ajudar os médicos a determinar taxas aceitáveis de deterioração do campo visual em pacientes com glaucoma


Subject(s)
Humans , Visual Fields , Glaucoma/complications , Glaucoma/diagnosis , Linear Models , Glaucoma/physiopathology , Blindness/etiology , Risk Factors , Disease Progression , Visual Field Tests/methods , Intraocular Pressure
5.
Rev. bras. oftalmol ; 79(1): 53-55, Jan.-Feb. 2020. graf
Article in Portuguese | LILACS | ID: biblio-1092660

ABSTRACT

Resumo A reversão da escavação é uma entidade rara que se refere à redução da escavação do disco óptico em resposta à diminuição sustentada dos níveis de pressão intra-ocular (PIO), em cerca de 25% da PIO basal. A ocorrência deste fenômeno apenas com o tratamento clínico é pouco relatada na literatura, Este estudo relata um caso de um paciente com glaucoma juvenil, que apresentou à gonioscopia ângulo aberto e tomografia de coerência óptica (OCT) com uma diminuição significativa na camada de fibras nervosas retinianas em ambos os olhos. Após um ano utilizando análogos de prostaglandina tópica e manutenção de níveis baixos de PIO, ocorreu diminuição da escavação do nervo óptico, que foi confirmada pelos padrões topográficos da OCT. O "reversal of cupping" é um sinal da diminuição da tensão ao nível da lâmina crivosa e está provavelmente associada a uma redução do risco para a progressão do glaucoma a longo prazo, sem melhora da função visual.


Abstract Reversal of cupping is a rare entity, characterized by the reduction of optical disc cupping in response to sustained decrease in intraocular pressure (IOP) levels by 25% of the basal IOP. The occurrence of this phenomenon with clinical treatment is rarely reported in the literature. This study reports a case of a patient with juvenile glaucoma with augmented cupping, significant decrease in the retinal nerve fiber layer in both eyes and altered topografic measures in optical coherence tomography (OCT). After one year using topical prostaglandin analog and keeping low IOP levels, a decrease in optic nerve cupping was detected in rethinography, confirmed by the improvement of OCT topographic measures. Reversal of cupping is a sign of decreased tension at the level of the lamina cribosa and is probably associated with a reduced risk for long-term progression of glaucoma without improvement of visual function.


Subject(s)
Humans , Male , Adult , Optic Disk/pathology , Glaucoma/diagnosis , Glaucoma/drug therapy , Intraocular Pressure/drug effects , Ophthalmic Solutions/therapeutic use , Ophthalmoscopy , Prostaglandins, Synthetic/therapeutic use , Timolol/therapeutic use , Tonometry, Ocular , Visual Acuity , Glaucoma/physiopathology , Tomography, Optical Coherence , Fundus Oculi , Gonioscopy
6.
Arq. bras. oftalmol ; 82(6): 463-470, Nov.-Dec. 2019. tab, graf
Article in English | LILACS | ID: biblio-1038693

ABSTRACT

ABSTRACT Purpose: To evaluate the impact of visual acuity, visual field damage, and other factors on the quality of life in Brazilian patients with glaucoma. Methods: This cross-sectional prospective study involved 49 patients with glaucoma enrolled based on the presence of reproducible standard automated perimetry defects in at least one eye at the time of evaluation. A detailed ophthalmologic examination was performed on each patient. All patients had reproducible standard automated perimetry and completed an NEI VFQ-25 questionnaire. The associations of the quality of life scores to the best-corrected visual acuity and the visual field loss of the better and worse eyes were investigated. Results: The mean quality of life score of the patients was 58.8 ± 18.7 units. The highest and lowest mean values (85.0 ± 24.2 and 37.5 ± 36.5 units) were observed in the "Social Functioning Subscale" and "Driving Subscale," respectively. Patients with advanced glaucoma (mean deviation <-12 dB) in the worse eye had significantly lower quality of life scores (p=0.007). There was a significant correlation between the quality of life scores and the visual acuity of the better and worse eyes (r2=13%, p=0.010 and r2=32%, p<0.001, respectively). There was also a significant correlation between the quality of life scores and standard automated perimetry mean deviation of the better and worse eyes (r2=13%, p=0.023 and r2=47%, p<0.001, respectively). In a multivariate model containing so­cioeconomic and comorbidity indices, quality of life remained significantly related to the standard automated perimetry mean deviation of the better and worse eyes (r2=23%, p=0.29 and r2=49%, p<0.001, respectively) as well as to the visual acuity of the better and worse eyes (r2=18%, p=0.017 and r2=40%, p<0.001, respectively). Conclusion: The standard automated perimetry mean deviation and the visual acuity of the better and worse eyes were associated with lower quality of life in Brazilian patients with glaucoma. Quality of life was mostly highly associated with the standard automated perimetry mean deviation of the worse eye.


RESUMO Objetivo: Avaliar o impacto da acuidade visual, danos no campo visual e outros fatores na qualidade de vida em pacientes brasileiros com glaucoma. Métodos: Este foi um estudo transversal prospectivo incluindo 49 pacientes com glau­coma selecionados com base na presença de defeitos por perimetria automatizada padrão reprodutíveis em pelo menos um olho no momento da avaliação. Um exame oftalmológico detalhado foi realizado em cada paciente. Todos os pacientes possuíam perimetria automatizada padrão reprodutível e preencheram um questionário NEI VFQ-25. As associações dos escores de qualidade de vida à acuidade visual melhor corrigida e à perda de campo visual dos melhores e piores olhos foram investigadas. Resultados: A média dos escores de qualidade de vida dos pacientes foi de 58,8 ± 18,7 unidades. Os maiores e menores valores médios (85,0 ± 24,2 e 37,5 ± 36,5 unidades) foram observados nas subescalas "Social Functioning Subscale" e "Driving Subscale", respectivamente. Pacientes com glaucoma avançado (desvio médio <-12 dB) no pior olho tiveram escores de qualidade de vida significativamente menores (p=0,007). Houve correlação significativa entre escores de qualidade de vida e a acuidade visual dos olhos melhores e piores (r2=13%; p=0,010 e r2=32%; p<0,001; respectivamente). Houve também uma correlação significativa entre os escores de qualidade de vida e desvios médios da perimetria automatizada padrão dos olhos melhores e piores (r2=13%; p=0,023 e r2=47%; p<0,001; respectivamente). Em um modelo multivariado contendo dados socioeconômicos e de comorbidades, a qualidade de vida permaneceu significativamente relacionada ao desvio médio padrão da perimetria automatizada do olho melhor e pior (r2=23%; p=0,29 e r2=49%; p<0,001, respectivamente) bem como para a acuidade visual do olho melhor e pior (r2=18%; p= 0,017 e r2=40%; p<0,001, respectivamente). Conclusão: O desvio padrão da perimetria automatizada padrão e a acuidade visual dos olhos melhor e pior foram associados à menor qualidade de vida em pacientes brasileiros com glaucoma. A qualidade de vida foi em grande parte altamente associada ao desvio padrão da perimetria automatizada padrão do pior olho.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Quality of Life , Visual Acuity/physiology , Visual Fields/physiology , Glaucoma/physiopathology , Reference Values , Socioeconomic Factors , Brazil , Linear Models , Cross-Sectional Studies , Prospective Studies , Surveys and Questionnaires , Visual Field Tests , Intraocular Pressure
7.
Arq. bras. oftalmol ; 82(5): 381-388, Sept.-Oct. 2019. tab, graf
Article in English | LILACS | ID: biblio-1019440

ABSTRACT

ABSTRACT Purpose: To evaluate the effectiveness in in­traocular pressure reduction and safety of micropulse trans­scleral diode cyclophotocoagulation in refractory glaucoma. Methods: We prospectively evaluated a case series of 21 eyes of 21 consecutive patients with refractory glaucoma treated with micropulse transscleral diode cyclophotocoagulation at 12-month follow-up. The total treatment time was at the discretion of the surgeon, considering baseline and target intraocular pressure and glaucoma diagnosis. Intraocular pressure, inflammation, visual acuity, and number of medications were monitored. Success was defined as intraocular pressure between 6 and 21 mmHg and/or 30% reduction from baseline intraocular pressure with or without the use of antiglaucoma medications. Visual acuity loss was defined as a loss of ≥2 lines of vision on the Snellen chart or a ≥2-level decrease in visual function in patients with nonmeasurable chart acuity. Results: The mean age was 61.04 ± 12.99 years, and 11 (52.4%) patients were male, with most (95%) patients showing low visual acuity at baseline (count fingers or worse). The mean intraocular pressure was 33.38 ± 15.95 mmHg, and the mean number of medications was 3.5 ± 1.1 at baseline. After 1, 3, 6, and 12 months, 76.19%, 57.14%, 55.56%, and 66.67%, respectively, of the patients were classified as treatment successes. Seven (33.3%) patients required new laser treatment and were considered treatment failures. The mean intraocular pressure reduction was 44.72% ± 29.72% in the first week and 41.59% ± 18.93% at the end of follow-up (p=0.006). The mean number of medications significantly dropped to 2.00 ± 1.7 at the 12-month visit (p=0.044). Complications included hypotony (4.8%), intraocular inflammation after 1 month (19%), and visual acuity loss (4.8%). Conclusions: Micropulse transscleral diode cyclophotocoagulation was safe and effective for reducing intraocular pressure in eyes with refractory and advanced glaucoma, with reduced need for ocular antihypertensive medication.


RESUMO Objetivo: Avaliar a eficácia na redução da pressão intraocular e na segurança da ciclofotocoagulação com laser de diodo transescleral em glaucoma refratário. Métodos: Avaliamos prospectivamente uma série de casos de 21 olhos de 21 pacientes com glaucoma refratário tratados com ciclofotocoagulação com laser de diodo transescleral com acompanhamento por 12 meses. O tempo total de tratamento ficou a critério do cirurgião, considerando a pressão intraocular inicial e alvo e o tipo de glaucoma. Pressão intraocular, inflamação, acuidade visual e número de medicamentos foram monitorados. O sucesso foi definido como pressão intraocular entre 6 e 21 mmHg e/ou redução de 30% da pressão intraocular basal com ou sem o uso de medicamentos glaucomatosos. Perda da acuidade visual foi definida como perda de ≥2 linhas de visão na tabela de Snellen ou uma diminuição de ≥ 2 níveis na função visual em pacientes com acuidade do gráfico não mensurável. Resultados: A idade média foi de 61,04 ± 12,99 anos e 11 (52,4%) pacientes eram do sexo masculino, com a maioria (95%) dos pacientes apresentando baixa acuidade visual inicialmente (conta dedos ou pior). A pressão intraocular média foi de 33,38 ± 15,95 mmHg, e o número médio de medicamentos foi de 3,5 ± 1,1, no início do estudo. Após 1, 3, 6 e 12 meses, 76,19%, 57,14%, 55,56% e 66,67%, respectivamente, dos pacientes foram classificados como sucesso do tratamento. Sete (33,3%) pacientes necessitaram de novo tratamento com laser e foram considerados falhas no tratamento. A redução média da pressão intraocular foi de 44,72% ± 29,72% na primeira semana e 41,59% ± 18,93% no final do seguimento (p=0,006). O número médio de medicamentos diminuiu significativamente para 2,00 ± 1,7 na visita de 12 meses (p=0,044). As complicações incluíram hipotonia (4,8%), inflamação intraocular após 1 mês (19%) e perda de acuidade visual (4,8%). Conclusões: A ciclofotocoagulação com laser de diodo transescleral foi segura e eficaz para reduzir a pressão intraocular em olhos com glaucoma refratário e avançado, com necessidade reduzida de hipotensores oculares.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Glaucoma/surgery , Laser Coagulation/methods , Visual Acuity , Glaucoma/physiopathology , Glaucoma, Neovascular/surgery , Ciliary Body/surgery , Ciliary Body/physiopathology , Prospective Studies , Laser Coagulation/instrumentation , Intraocular Pressure
8.
Rev. bras. oftalmol ; 78(3): 179-182, May-June 2019. graf
Article in Portuguese | LILACS | ID: biblio-1013673

ABSTRACT

RESUMO Os AA fazem considerações sobre clínica, diagnóstico e tratamento do Glaucoma Facomórfico, e ilustram com a apresentação e discussão em quatro pacientes.


ABSTRACT The AA present Phacomorphic Glaucoma discussing the clinic presentation, diagnose and treatment of the disease in four patients.


Subject(s)
Humans , Female , Adult , Middle Aged , Glaucoma/surgery , Glaucoma/diagnosis , Glaucoma/physiopathology , Intraocular Pressure , Cataract , Cataract Extraction/methods , Phacoemulsification/methods , Lens Implantation, Intraocular , Anterior Chamber
9.
Rev. bras. oftalmol ; 78(3): 162-165, May-June 2019. tab, graf
Article in Portuguese | LILACS | ID: biblio-1013675

ABSTRACT

RESUMO Objetivo: Comparar o resultado entre dois tipos de tonômetros, tendo como padrão ouro a tonometria de aplanação, relacionando com a espessura corneana e suas validações como instrumentos de rastreio populacional. Métodos: Estudo transversal comparativo, realizado com 400 olhos do ambulatório de oftalmologia da Adachi Oftalmologia, em Macapá (Amapá), entre os valores médios da pressão ocular medidos pelo tonômetro Icare®, o Tonômetro Pneumático e o Tonômetro de Aplanação de Goldmann em função da espessura corneana. Foram divididos conforme a ECC em 3 grupos. Grupo 1: 260 olhos com ECC< 530µ; grupo 2: 217 olhos com ECC entre 530µ e 590µ; e, grupo 3: 157 olhos com ECC>590µ. Resultados: A ECC média obtida na paquimetria foi de 557µ, variando de 651µ a 477µ (desvio padrão de 32.9). A PIO média obtida pela TP foi de 19,4 mmHg (com desvio padrão de 2,32); pelo Icare® foi de 16,7mmHg (desvio padrão de 2,12); e, na TAG foi de 15.5 mmHg (desvio padrão de 2,02). Para paquimetrias inferiores a 530µ e superiores a 590µ a PIOm não diferiu significativamente entre a TAG e Icare® (p = 0,232), sendo estatisticamente significativa diferença obtida para córneas com ECC entre 530 e 590 µ. A PIOm obtida pelo TP foi significativamente maior do que a pressão ocular média dos TAG e Icare® (p < 0,001 para ambos) em todos os grupos. Conclusões: Os três métodos podem ser utilizados em campanhas de rastreamento, porém o Icare® se mostrou mais confiável que a TP, com valores obtidos estatisticamente mais confiáveis quando comparados à TP. Existe suficiente concordância entre o Icare e a TAG para recomendar o seu uso.


ABSTRACT Objective: To compare the result between two types of tonometres, using as gold standard the aplanation tonometry, relating to the corneal thickness and its validations as instruments of population screening. Methods: A comparative cross-sectional study was carried out with 400 eyes from the ophthalmology clinic of Adachi Ophthalmology, in Macapá (Amapá), between the mean values of ocular pressure measured by the Icare® tonometro, the Pneumatic Tonometer and the Goldmann Flattening Tonometro as a function of corneal thickness. They were divided according to ECC in 3 groups. Group 1: 260 eyes with ECC <530µ; group 2: 217 eyes with ECC between 530µ and 590µ; and, group 3: 157 eyes with ECC> 590µ. Results: The mean ECC obtained in pachymetry was 557µ, ranging from 651µ to 477µ (standard deviation of 32.9). The mean IOP obtained by PT was 19.4 mmHg (with a standard deviation of 2.32); by Icare® was 16.7mmHg (standard deviation of 2.12); and in the TAG it was 15.5 mmHg (standard deviation of 2.02). For pachymetry less than 530µ and greater than 590µ, PIOm did not differ significantly between TAG and Icare® (p = 0.232), and a statistically significant difference was obtained for corneas with ECC between 530 and 590 µ. The IOP obtained by the PT was significantly higher than the mean ocular pressure of the TAG and Icare® (p <0.001 for both) in all groups. Conclusions: All three methods can be used in screening campaigns, but Icare® proved to be more reliable than TP, with values obtained statistically more reliable when compared to TP. There is sufficient agreement between Icare and TAG to recommend its use.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Tonometry, Ocular/instrumentation , Tonometry, Ocular/methods , Glaucoma/diagnosis , Ocular Hypertension/diagnosis , Intraocular Pressure/physiology , Glaucoma/physiopathology , Cross-Sectional Studies , Air , Equipment Design , Corneal Pachymetry
10.
Arq. bras. oftalmol ; 82(3): 245-252, May-June 2019. graf
Article in English | LILACS | ID: biblio-1001298

ABSTRACT

ABSTRACT Glaucoma is the leading cause of irreversible blindness worldwide and can affect a broad array of daily activities, including driving. Recently, studies investigating the relationship between driving performance and glaucoma have received a great deal of interest. Assessment of driving behavior is not straightforward because driving is a complex skill involving significant multi-tasking ability. In this review, we summarize recent work from clinical studies investigating how glaucoma can affect driving performance. Patients with glaucoma are more likely to be involved in motor vehicle collisions when compared to healthy subjects. Here we describe how conventional functional tests performed in glaucoma patients, such as visual field measurements via standard automatic perimetry, are associated with driving performance. However, the risk of motor vehicle collisions is not entirely attributable to visual field impairment in glaucoma, suggesting that other factors also account for both driving safety and performance. Finally, we show different studies suggesting that parameters from driving simulators can be helpful because they can identify the impact of visual loss on complex situations.


RESUMO O glaucoma é a principal causa de cegueira irreversível em todo o mundo e pode afetar uma ampla gama de atividades diárias, incluindo a direção veicular. Recentemente, estudos que investigam a relação entre o desempenho na condução veicular e o glaucoma têm recebido grande interesse. A avaliação do comportamento de dirigir não é direta porque dirigir é uma habilidade complexa que envolve habilidade multitarefa significativa. Nesta revisão, resumimos trabalhos recentes de estudos clínicos que investigam como o glaucoma pode afetar o desempenho na direção. Pacientes com glaucoma têm maior probabilidade de se envolverem em colisões de veículos motorizados quando comparados a indivíduos saudáveis. Descrevemos aqui como os testes funcionais convencionais realizados em pacientes com glaucoma, como as medições de campo visual por meio de perimetria automática padrão, estão associados ao desempenho na direção. No entanto, o risco de colisão de veículo motorizado não é totalmente atribuível ao comprometimento do campo visual no glaucoma, sugerindo que outros fatores também são responsáveis pela segurança e pelo desempenho. Finalmente, mostramos diferentes estudos sugerindo que os parâmetros dos simuladores de direção podem ser úteis porque eles podem identificar o impacto da perda visual em situações de complexas.


Subject(s)
Humans , Automobile Driving , Glaucoma/physiopathology , Risk Assessment/methods , Disability Evaluation , Attention/physiology , Vision Tests/methods , Computer Simulation , Accidents, Traffic , Visual Acuity/physiology , Visual Fields/physiology , Risk Factors
11.
Arq. bras. oftalmol ; 82(1): 6-11, Jan.-Feb. 2019. tab
Article in English | LILACS | ID: biblio-973873

ABSTRACT

ABSTRACT Purpose: Obesity is associated with eye diseases, but the underlying structural changes and pathogenic mechanisms have not been examined in detail. Here, we assessed the effects of morbid obesity on the morphometric indices of eye disease. Methods: Morbidly obese volunteers (n=101, body mass index [BMI] ³40) and healthy individuals (n=95, BMI: 18.50-24.99) were examined by Goldman applanation tonometry, pachymetry, and spectral domain optical coherence tomography. Intraocular pressure, anterior chamber depth, axial length, central corneal thickness, retinal nerve fiber layer thickness, central foveal thickness, and choroidal thickness were compared between groups. Results: Uncorrected intraocular pressure was significantly greater in the morbidly obese group than in the healthy control group (15.5 ± 2.5 vs. 14.5 ± 2.6 mmHg, p=0.009), whereas axial length, anterior chamber depth, and central corneal thickness did not differ between the groups. The mean retinal nerve fiber layer thickness at the temporal quadrant was reduced in the morbidly obese group (72.7 ± 13.6 vs. 85.05 ± 52.6 mm, p=0.024). Similarly, the mean retinal thicknesses at nasal and temporal 1500-mm locations were lower in the morbidly obese group (346.6 ± 18.2 vs. 353.7 ± 18.8 mm, p=0.008; 323.1 ± 20.3 vs. 330.0 ± 18.9 mm, p=0.001). The mean choroidal thickness was also reduced in almost all measurement locations (fovea, temporal 500 and 1000 mm, and nasal 500, 1000, and 1500 mm) of the obese group (p<0.05). Weight and BMI were negatively correlated with subfoveal choroidal thickness (r=-0.186, p=0.009; r=-0.173, p=0.015). Conclusion: Morbid obesity is associated with elevated uncorrected intraocular pressure and signs of neuropathy and retinopathy. Obesity may thus increase the risks of glaucoma and glaucomatous optic neuropathy.


RESUMO Objetivo: A obesidade está associada a doenças oulares, mas as mudanças estruturais subjacentes e os mecanismos patogênicos não foram examinados detalhadamente. Aqui avaliamos os efeitos da obesidade mórbida nos índices morfométricos da doença ocular. Métodos: Voluntários obesos mórbidos (n=101, índice de massa corporal ³40) e indivíduos saudáveis (n=95, índice de massa corporal 18,50 a 24,99) foram examinados por tonometria de aplanação de Goldman, paquimetria e tomografia de coerência óptica de domício espectral. A pressão intraocular, profundidade da câmara anterior, comprimento axial, espessura central da córnea, espessura da camada de fibras nervosas da retina, espessura foveal central e espessura da coroide foram comparadas entre os grupos. Resultados: A pressão intraocular não corrigida foi significativamente maior no grupo com obesidade mórbida do que no grupo controle saudável (15,5 ± 2,5 vs. 14,5 ± 2,6 mmHg, p=0,009), enquanto que o comprimento axial, profundidade da câmara anterior e espessura central da córnea não diferiram entre os grupos. A espessura média da camada de fibras nervosas da retina no quadrante temporal foi reduzida no grupo com obesidade mórbida (72,7 ± 13,6 vs. 85,05 ± 52,6 mm, p=0,024). Da mesma forma, a média das espesuras da retinianas nas localizações nasal e temporal de 1500 m foi menor no grupo com obesidade mórbida (346,6 ± 18,2 mm vs. 353,7 ± 18,8 mm, p=0,008; 323,1 ± 20,3 mm vs. 330,0 ± 18,9 mm, p=0,001). A espessura média da coroide também foi reduzida em quase todos os locais de mensuração (fóvea, temporal 500 e 1000 mm, nasal 500, 1000 e 1500 mm) do grupo obeso (p<0,05). Peso e índice de massa corporal foram negativamente correlacionados com a espessura da coroide subfoveal (r=-0,186, p=0,009; r=-0,173, p=0,015). Conclusão: A obesidade mórbida está associada à elevada pressão intraocular não corrigida e a sinais de neuropatia e retinopatia. A obesidade pode, assim, aumentar os riscos de glaucoma e neuropatia óptica glaucomatosa.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Young Adult , Retinal Diseases/etiology , Obesity, Morbid/complications , Choroid Diseases/etiology , Retina/pathology , Retinal Diseases/physiopathology , Tonometry, Ocular/methods , Obesity, Morbid/physiopathology , Body Mass Index , Case-Control Studies , Choroid Diseases/physiopathology , Glaucoma/etiology , Glaucoma/physiopathology , Choroid/pathology , Statistics, Nonparametric , Tomography, Optical Coherence/methods , Corneal Pachymetry/methods , Intraocular Pressure
12.
Arq. bras. oftalmol ; 81(2): 110-115, Mar.-Apr. 2018. tab
Article in English | LILACS | ID: biblio-950439

ABSTRACT

ABSTRACT Purpose: To compare the anterior segment parameters of patients with pseudoexfoliation syndrome, patients with pseudoexfoliation glaucoma, and normal subjects. Methods: This prospective, controlled, comparative study included 150 eyes of 150 patients. The patients were divided into the pseudoexfoliation syndrome group, the pseudoexfoliation glaucoma group, and the control group (50 patients in each group). Axial length, central corneal thickness, aqueous depth, anterior chamber depth, lens thickness, K1 and K2 keratometry values, and white to white distance measurements were obtained by optical biometry and compared between the groups. Results: The mean ages of the pseudoexfoliation syndrome, pseudoexfoliation glaucoma, and control patients were 62.18 ± 6.21, 61.80 ± 6.62, and 59.40 ± 6.89 years, respectively. There were no statistically significant differences between the groups in mean age or sex ratio (p>0.05). Mean central corneal thickness was statistically significantly greater, mean aqueous depth and anterior chamber depth were statistically significantly greater, and mean lens thickness was statistically significantly less in the control group than in the pseudoexfoliation syndrome and pseudoexfoliation glaucoma groups (p<0.05). Pairwise comparisons of the pseudoexfoliation syndrome group and the pseudoexfoliation glaucoma group revealed that there were no significant differences between these two groups in central corneal thickness, aqueous depth, anterior chamber depth, and lens thickness (p>0.017). Conclusions: Patients with pseudoexfoliation glaucoma and pseudoexfoliation syndrome had greater lens thickness, shallower aqueous depth and anterior chamber depth, and less central corneal thickness than normal subjects. None of the anterior segment parameters differed between patients with pseudoexfoliation syndrome and patients with pseudoexfoliation glaucoma.


RESUMO Objetivos: Comparar os parâmetros do segmento anterior de casos de síndrome de pseudo-esfoliação, de glaucoma pseudo-esfoliação e de indivíduos normais. Métodos: O presente estudo prospectivo comparativo controlado incluiu 150 olhos de 150 pacientes. Os pacientes foram divididos em três grupos: grupo síndrome de pseudo-esfoliação, grupo glaucoma pseudo-esfoliação e grupo controle (50 em cada grupo). O comprimento axial, a espessura corneana central, a profundidade aquosa, a profundidade da câmara anterior, a espessura da lente, os valores de ceratometria K1 e K2 e as medidas branco a branco, obtidas por biometria óptica, foram comparados entre os grupos. Resultados: As idades médias dos indivíduos do grupo síndrome de pseudo-esfoliação, glaucoma pseudo-esfoliação e controle foram 62,18 ± 6,21, 61,80 ± 6,62 e 59,40 ± 6,89 anos, respectivamente. Entre os grupos, não houve diferenças estatisticamente significativas quanto às idades e ao gênero dos pacientes (p>0,05, para todos). A espessura da córnea central média foi significativamente mais espessa, a profundidade média aquosa e a profundidade da câmara anterior foram significativamente mais profundas e a espessura média da lente foi significativamente mais fina no grupo controle do que nos grupos síndrome de pseudo-esfoliação e glaucoma pseudo-esfoliação (p<0,05, para todos). As comparações por pares do grupo síndrome de pseudo-esfoliação e do grupo glaucoma pseudo-esfoliação (p<0,05, para todos). As comparações por pares do grupo síndrome de pseudo-esfoliação e do grupo glaucoma pseudo-esfoliação não revelaram diferenças significativas entre esses dois grupos quanto à espessura corneana central, à profundidade aquosa, à profundidade da câmara anterior e aos valores de espessura da lente (p>0,017, para cada um). Conclusões: Os casos de glaucoma pseudo-esfoliação e de síndrome de pseudo-esfoliação apresentaram lente mais espessa, menor profundidade aquosa, menor profundidade da câmara anterior e espessura corneana central mais fina do que os indivíduos normais. No entanto, nenhum dos parâmetros do segmento anterior foi diferente entre os indivíduos do grupo síndrome de pseudo-esfoliação e do grupo glaucoma pseudo-esfoliação.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Glaucoma/pathology , Exfoliation Syndrome/pathology , Anterior Eye Segment/pathology , Reference Values , Visual Acuity , Case-Control Studies , Glaucoma/physiopathology , Prospective Studies , Analysis of Variance , Exfoliation Syndrome/physiopathology , Statistics, Nonparametric , Corneal Topography/methods , Corneal Pachymetry/methods , Intraocular Pressure , Anterior Eye Segment/physiopathology
13.
Arq. bras. neurocir ; 37(3): 190-195, 2018.
Article in English | LILACS | ID: biblio-1362857

ABSTRACT

The brain represents 2% of the adult body mass; conversely, it is responsible for 20% to 25% of the glucose and 20% of the oxygen consumption, receiving 15% of the cardiac output. This substantial metabolic rate is associated with a significant production of biological debris, which is potentially toxic. Therefore, a complex and efficient clearance system is required to prevent the accumulation of byproducts and ensure optimal function. However, until today, there is little knowledge about this topic. The glymphatic system, also known as perivascular pathway, is a recently described glialdependent network that is responsible for the clearance of metabolites from the central nervous system (CNS), playing a role equivalent to the one played by the lymphatic vessels present in other organs. Studies have demonstrated that the glymphatic pathway has a paramount role in protein homeostasis, and that the malfunction of this system may be related to the development of neurodegenerative disorders such as Alzheimer disease and normal pressure hydrocephalus. They also showed that body posture, exercise and the state of consciousness influence the glymphatic transport. In this context, the understanding of this clearance system could not only clarify the pathophysiology of several diseases, but also contribute to future therapeutic interventions. In the present article, we will evaluate the glymphatic pathway, focusing on the factors that regulate its flow, as well as on its role in CNS physiology and in disease initiation and progression, including dementia, hydrocephalus, glaucoma and traumatic brain injury. Ultimately, this review also aims to encourage further research on novel therapeutic targets.


Subject(s)
Humans , Animals , Neurodegenerative Diseases/physiopathology , Glymphatic System/physiology , Sleep/physiology , Aging/physiology , Metabolic Clearance Rate , Glaucoma/physiopathology , Brain Injuries, Traumatic/physiopathology , Glymphatic System/physiopathology , Glymphatic System/metabolism , Hydrocephalus, Normal Pressure/physiopathology
14.
Arq. bras. oftalmol ; 80(5): 309-312, Sept.-Oct. 2017. tab
Article in English | LILACS | ID: biblio-888139

ABSTRACT

ABSTRACT Purpose: To evaluate the corneal biomechanical features and central corneal thickness in ankylosing spondylitis patients and to evaluate correlations of these parameters with disease activity. Methods: The study included 51 patients diagnosed with ankylosing spondylitis (mean age, 40.80 ± 13.15 years; range, 18-72 years) and 34 age- and sex-matched healthy controls (mean age, 42.00 ± 12.32 years; range, 18-60 years). All underwent a complete ophthalmological and physical examination, including visual acuity testing and biomicroscopic anterior and posterior segment examinations. Corneal hysteresis, corneal resistance factor, Goldmann-correlated intraocular pressure, and corneal compensated intraocular pressure were evaluated with an ocular response analyzer, and the central corneal thickness was measured with Sirius® corneal tomography. The Bath Ankylosing Spondylitis Disease Activity Index, Functional Index, and Metrology Index scores were recorded. Results: In the ankylosing spondylitis patients, the mean disease duration was 7.73 ± 6.05 (range, 1-30) years. There was no statistically significant difference between the patients and controls in the corneal biomechanical features. The Goldmann-correlated intraocular pressure and corneal compensated intraocular pressure both showed positive correlations with age (p=0.003 and p=0.001, res­pectively). There was a negative correlation between corneal hysteresis and disease duration (p=0.002), and between central corneal thickness and the Bath Ankylosing Spondylitis Metrology Index score (p=0.003). Conclusion: This study demonstrated a significant negative correlation between corneal hysteresis and disease duration in ankylosing spondylitis patients. Furthermore, the central corneal thickness value decreased with an increase in Bath Ankylosing Spondylitis Metrology Index score, which may result in an underestimate of intraocular pressure readings and thus an inaccurate risk assessment of glaucoma.


RESUMO Objetivo: Avaliar as características biomecânicas da córnea e espessura central da córnea em pacientes com espondilite anquilosante e analisar a correlação destes parâmetros no grupo de estudo com a atividade da doença. Métodos: Foram incluídos no estudo 51 pacientes com diagnóstico de espondilite anquilosante e 34 controles saudáveis com idade e sexo. Todos os sujeitos foram submetidos a um exame oftalmológico e físico completo, incluindo exames de acuidade visual, exames de segmento anterior e posterior biomicroscópicos. Foram avaliados o coeficiente de resistência da córnea, a pressão intraocular correlacionada com Goldmann e a pressão intraocular compensada da córnea com o analisador de resposta ocular, a espessura corneana central com a tomografia corneana pelo Sirius®. Se o índice de atividade da doença de espondilite anquilosante de banho, o índice funcional de espondilite anquilosante de banho, o índice de metrologia de espondilite anquilosante de banho. Resultados: Foram incluídos no estudo 51 pacientes com idade média de 40,80 ± 13,15 (intervalo: 18-72) anos e 34 casos de controle com idade média de 42,00 ± 12,32 (intervalo: 18-60) anos. No grupo espondilite anquilosante a duração média da doença foi de 7,73 ± 6,05 (1,00-30,00) anos. Não houve diferença estatisticamente significante entre dois grupos quanto às características biomecânicas da córnea. Na análise de correlação, no grupo de estudo; pressão intraocular correlacionada com Goldmann e pressão intraocular compensada da córnea estavam positivamente correlacionados com a idade (p=0,003, p=0,001, respectivamente). Houve uma correlação negativa entre a duração da doença e CH (p=0,002), e entre índice de metrologia de espondilite anquilosante de banho e espessura corneana central (p=0,003). Conclusão: Este estudo demonstrou correlação negativa significativa entre a duração da doença e a histerese corneal em pacientes com espondilite anquilosante. Além disso, com um aumento na pontuação de índice de metrologia de espondilite anquilosante de banho, o valor de espessura corneana central também estava di­minuindo o que pode causar uma diminuição nas leituras de pressão intraocular artificialmente e resultar em avaliação de risco imprecisa de glaucoma.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged , Young Adult , Spondylitis, Ankylosing/pathology , Cornea/pathology , Corneal Diseases/pathology , Spondylitis, Ankylosing/complications , Biomechanical Phenomena , Severity of Illness Index , Case-Control Studies , Cell Count , Glaucoma/etiology , Glaucoma/physiopathology , Risk Factors , Cornea/physiopathology , Corneal Diseases/complications , Corneal Diseases/physiopathology , Corneal Topography , Corneal Pachymetry , Intraocular Pressure
15.
Arq. bras. oftalmol ; 80(3): 202-206, May-June 2017. tab, graf
Article in English | LILACS | ID: biblio-888109

ABSTRACT

ABSTRACT Purpose: Studies have suggested that corneal biomechanical properties influence intraocular pressure (IOP) measurements, namely central corneal thickness (CCT) and corneal hysteresis (CH). The present study aimed to investigate the associations of CH and CCT with glaucoma development. Methods: We performed a review of the literature and meta-analysis of observational studies (2006-2016) that included both adult glaucoma patients and controls and reported CCT and CH as outcomes. Nineteen studies were conside red eligible, and the mean difference (MD) between groups (patient and control) for both variables was used for statistical analyses. Results: A total of 1,213 glaucoma and 1,055 healthy eyes were studied. Quan titative analysis suggested that CH was significantly lower in the glaucoma group than in the control group (MD=-1.54 mmHg, 95% CI [-1.68, -1.41], P<0.0001). Additionally, CCT was significantly lower in the glaucoma group than in the control group (MD=-8.49 µm, 95% CI [-11.36, -5.62], P<0.001). Conclusion: Corneal properties appear to differ between glaucoma patients and healthy controls. Our results emphasize the importance of corneal biomechanical properties in IOP interpretation and should support further studies on the influence of CH and CCT in glaucoma screening and diagnosis.


RESUMO Objetivo: A literatura sugere que as propriedades biomecânicas da córnea, nomeadamente a espessura central da córnea (ECC) e a histerese corneana (HC), influenciam a medição da pressão intraocular (PIO). Este estudo teve como objetivo investigar a associação entre a ECC e a HC e o desenvolvimento de glaucoma. Métodos: Revisão da literatura e meta-análise. Foram incluídos estudos observacionais, publicados entre 2006 e 2016, que integrassem um grupo controle e um grupo de pacientes com glaucoma em que estes dois grupos apresentassem, igualmente, a ECC e a HC como parâmetros. Dezenove estudos foram considerados elegíveis e a diferença média (MD) daqueles parâmetros nos dois grupos foi utilizada para análise estatística. Resultados: Estudaram-se um total de 1.213 olhos com glaucoma e 1.055 olhos saudáveis. A análise quantitativa revelou que a HC é significativamente mais baixa no grupo de doentes com glaucoma quando comparada com o grupo controle (MD=-1,54 mmHg, intervalo de confiança de 95% [-1,68-1,41], P<0,00001). A ECC foi, também, significativamente mais baixa no grupo glaucoma quando comparada com os indivíduos saudáveis MD=-8,49 µm, intervalo de confiança de 95% [-11,36, -5,62], P<0,001). Conclusão: Os pacientes com glaucoma parecem possuir propriedades corneanas diferentes das que apresentam os indivíduos saudáveis. Os resultados enfatizam a importância das propriedades biomecânicas da córnea na interpretação da PIO e devem contribuir para novos estudos sobre a influência da HC e da ECC no rastreio e diagnóstico do glaucoma.


Subject(s)
Humans , Glaucoma/physiopathology , Cornea/physiopathology , Corneal Pachymetry , Intraocular Pressure/physiology , Reference Values , Biomechanical Phenomena/physiology , Case-Control Studies , Glaucoma/pathology , Risk Factors , Cornea/pathology , Observational Studies as Topic
16.
Arq. bras. oftalmol ; 79(5): 323-327, Sept.-Oct. 2016. tab, graf
Article in English | LILACS | ID: biblio-827969

ABSTRACT

ABSTRACT Purpose: To analyze the intrasession and intersession repeatability of contrast sensitivity (CS) measurements in patients with glaucoma, cataract, or age-related macular degeneration (AMD) and healthy controls. Methods: CS measurements were performed using the OPTEC-Functional Vision Analyzer (FVA), which uses a standardized and closed (view-in) system. Measurements for patients with glaucoma, cataract, or AMD and healthy controls were repeated within 30 minutes (intrasession) and during two sessions (intersession), separated by one week to one month. Test-retest reliability and correlation were measured using the intraclass correlation coefficient (ICC) and coefficient of repeatability (COR). Results: Ninety subjects (90 eyes) with visual acuity of 0.17 logMAR or higher in the cataract group or 0.00 logMAR in the other groups were included. During the first session, the ICC values were 0.87, 0.90, 0.76, and 0.69, and COR values were 0.24, 0.20, 0.38, and 0.25 for the control, glaucoma, cataract, and AMD groups, respectively. The reliability scores significantly improved during the second session, except in the glaucoma group. There was an acceptable floor effect and no ceiling effect at higher frequencies in the glaucoma and AMD groups. Conclusion: In subjects with good visual acuity, the FVA system is useful for evaluating CS and demonstrates good repeatability, as shown by ICC and COR. Because there is no ceiling effect, this system is beneficial for evaluation of early changes in CS, particularly in patients with glaucoma or AMD.


RESUMO Objetivo: Analisar a reprodutibilidade intrassessão e intersessão das medidas de sensibilidade ao contraste (CS) em pacientes com degeneração macular relacionada à idade (AMD), glaucoma e catarata. Método: As medidas de CS foram feitas pelo OPTEC-Funcional Visão Analyzer (FVA), que utiliza um sistema padronizado e fechado de avaliação da acuidade visual. Medidas em pacientes com AMD, glaucoma, catarata e nos controles saudáveis foram repetidas no prazo de 30 minutos (intrassessão) em duas visitas (intersessão), separadas por uma semana a um mês. A confiabilidade e correlação teste-reteste foram calculados por meio do coeficiente de correlação intraclasse (ICC) e coeficiente de reprodutibilidade (COR). Resultados: Noventa olhos de 90 indivíduos foram recrutados com acuidade visual de 0,17 logMAR ou melhor em catarata e 0,00 logMAR nos outros grupos. A confiabilidade da CS na primeira visita dos grupos normal, glaucoma, catarata e AMD foram, respectivamente, ICC 0,87; 0,90; 0,76; 0,69, e COR 0,24; 0,20; 0,38; 0,25. Os índices de confiabilidade foram significativamente melhorados nas segundas visitas, exceto no grupo glaucoma. Houve um efeito chão aceitável e nenhum efeito teto em frequências mais altas nos grupos glaucoma e AMD. Conclusões: Em indivíduos com boa acuidade visual, o sistema FVA de avaliação da CS é útil e apresenta boa confiabilidade, como mostrado pelas análises de ICC e COR. Por não apresentar efeito teto, este sistema parece ser benéfico para a avaliação das alterações precoces de CS, especialmente no glaucoma e AMD.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Cataract/physiopathology , Contrast Sensitivity/physiology , Glaucoma/physiopathology , Macular Degeneration/physiopathology , Reference Values , Time Factors , Vision Tests/instrumentation , Vision Tests/methods , Cataract/diagnosis , Case-Control Studies , Glaucoma/diagnosis , Prospective Studies , Reproducibility of Results , Age Factors , Statistics, Nonparametric , Macular Degeneration/diagnosis
17.
Arq. bras. oftalmol ; 79(4): 214-217, July-Aug. 2016. tab
Article in English | LILACS | ID: lil-794586

ABSTRACT

ABSTRACT Purpose: To evaluate variations in choroidal thickness (CT) during the water drinking test (WDT) in emmetropic eyes (EE) and highly myopic eyes (ME) using spectral-domain optical coherence tomography (SD-OCT). Methods: Clinical trial performed at a tertiary care hospital comprising 30 randomly selected eyes. The WDT and SD-OCT macular scans were performed 10 and 45 min after water ingestion in 15 myopic and 15 EE of 15 healthy patients in each group. Primary study outcomes were average macular CT measured by SD-OCT and intraocular pressure (IOP) during the WDT. Results: The mean spherical equivalent refraction was 0.15 ± 0.24 D in emmetropic and -7.1 ± 1.75 D in ME (p<0.001). No statistical differences between EE and ME were observed during the WDT response. EE had higher CT compared with ME at the fovea (361.4 ± 55.4 vs 257.9 ± 95.3; p<0.001), 3 mm nasal to the fovea (158.0 ± 71.8 vs 122.5 ± 54.5; p =0.047), and 3 mm temporally to the fovea (310.6 ± 52.4 vs 247.6 ± 90.1; p=0.05). Regarding CT variation, significant differences in foveal CT at 10 min after water ingestion were observed in both EE and ME, with no statistically significant difference observed between groups. A moderate correlation between IOP peak during the WDT and CT was demonstrated in ME (r=0.52; p=0.04). Conclusions: No statistically significant differences in CT variation during the WDT were observed between EE and ME, indicating similar behavior of the choroidal bed during the WDT in both groups. Further, CT was thinner in highly ME, with CT variation unable to explain elevations in IOP observed during the WDT.


RESUMO Objetivo: Avaliar a espessura de coroide (EC) e sua variação durante o teste de sobrecarga hídrica (TSH) em olhos emétropes (EE) e míopes (ME) utilizando a tomografia de coerência óptica Spectral-Domain (SD-OCT). Métodos: Ensaio clinico realizado em um hospital terciário. 30 olhos selecionados randomizadamente, 15 míopes e 15 emétropes de 15 pacientes em cada grupo foram submetidos ao TSH e scans maculares com SD-OCT realizados 10 e 45 minutos após a ingestão de água. Os principais resultados avaliados foram média da EC na região macular pelo SD-OCT e pressão intraocular (PIO) durante o TSH. Resultados: O equivalente esférico médio foi de 0.15 ± 0.24 dioptrias em emétropes e -7,1 ± 1,75 dioptrias nos olhos míopes (p<0,001). Não foram encontradas diferenças estatísticas durante a resposta ao TSH entre EE e ME. EE apresentaram maior EC em comparação com ME, tanto na região foveal (361,4 ± 55,4 vs 257,9 ± 95,3; p<0,001), 3 milímetros nasal à fóvea (158,0 ± 71,8 vs 122,5 ± 54,5; p=0,047) e 3 mm temporal à fóvea (310,6± 52.4 vs 247,6 ± 90,1; p=0,05). Em relação à variação da EC, diferenças estatisticamente significativas foram demonstrados na região foveal, 10 minutos após a ingestão de água em ambos EE e ME, sem diferenças entre os grupos. Moderada correlação entre pico de PIO durante o TSH e EC foi demonstrada em ME ( r=0,52; p=0,04). Conclusão: A diferença na variação da EC provocada pelo TSH não foi estatisticamente diferente entre olhos emétropes e míopes, o que sugere um comportamento semelhante da coroide nestes dois grupos quando submetidos ao TSH. Além disso, a EC é mais fina nos olhos alto míopes, e a variação na EC não explica o aumento da PIO durante o TSH.


Subject(s)
Humans , Male , Female , Adult , Young Adult , Drinking Water/administration & dosage , Choroid/pathology , Tomography, Optical Coherence/methods , Diagnostic Techniques, Ophthalmological , Myopia/pathology , Reference Values , Time Factors , Glaucoma/physiopathology , Glaucoma/pathology , Reproducibility of Results , Choroid/physiopathology , Axial Length, Eye , Fovea Centralis/physiopathology , Fovea Centralis/pathology , Intraocular Pressure/physiology , Myopia/physiopathology
18.
Rev. bras. oftalmol ; 75(3): 209-213, tab
Article in Portuguese | LILACS | ID: lil-787693

ABSTRACT

RESUMO Objetivo: Avaliar a utilidade do tonômetro de ar (TA) em estudos populacionais em indivíduos suspeitos de hipertensão ocular, comparando os valores com os fornecidos pelo tonômetro de aplanação de Goldmann (TG). Métodos: Estudo transversal, de amostra probabilística, composta por 11.452 indivíduos e"20 anos, compondo-se uma subamostra dos que apresentaram valores de pressão intraocular (PIO) obtidos com o TA e"20mmHg, nos quais a PIO foi repetida com o TG. Os resultados dos dois tonmetros foram comparados considerando sexo, cor da pele referida, lateralidade, relação escavação/disco (Â0,6; entre e"0,6 e <0,8; e"0,8) e diagnóstico. Foram consideradas três situações: não-portadores de glaucoma (NG), suspeitos (SG) e portadores de glaucoma (CG). Para comparação entre as medidas foi utilizado o teste t de Student para amostras pareadas e o teste de correlação de Pearson para avaliar a associação entre PIO, idade e tonometria. Resultados: Foram detectados 198 indivíduos (339 olhos) com PIOe"20mmHg com o TA, que tiveram a medida repetida com o TG. Foram considerados 233 olhos como NG, 47 olhos como SG e 19 olhos como CG. Em olhos com escavação e"0,8, a medida com TA e TG foram semelhantes. Nos NG e SG, o TA superestimou os valores. Houve associação entre aumento da PIO e aumento da idade com os dois tonmetros. Conclusão: Valores de PIO são superiores com TA comparados ao TG, principalmente quando a PIO é normal. Há concordância entre os métodos quando a PIO é alta e a escavação do nervo óptico é aumentada, o que valida a aplicação do TA em campanhas populacionais.


ABSTRACT Purpose: to evaluate the use of air tonometer (TA) in population studies in individuals suspected of ocular hypertension, comparing values with those provided by the Goldmann Tonometer (GT). Methods: a cross-sectional study was done using a probabilistic sample consisting of 11,452 individuals e"20 years old.A subsample composed by the individuals with IOP values obtained with TA e"20 mmHg was selected, in which IOP was repeated with the GT. The results of both tonometers were compared considering gender, referred color of skin, laterality, cup-to-disc ratio (Â0.6; e"0.6 and <0.8; e"0.8) and diagnosis, considering three situations: without glaucoma (NG), suspected glaucoma (SG) and patients with glaucoma (CG). The Student t test was used for paired samples and the Pearson correlation test to evaluate the association between IOP, age and tonometry. Results: we identified 198 individuals (339 eyes) with IOP e"20mmHg with the TA, who had the measures repeated with the GT. Two hundred and thirty-three eyes were considered as NG, 47 eyes as SG and 19 eyes as CG. In eyes with cup-to-disc ratio e"0.8, the TA and GT measurements were similar. In NG and SG, the TA overestimated values. There was an association between increased IOP and increasing age with both tonometers. Conclusion: IOP values are higher with TA compared to GT, especially when IOP is normal.There is agreement between the methods when IOP is high and the optic nerve excavation is increased, which validates the application of TA in population campaigns.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Tonometry, Ocular/instrumentation , Tonometry, Ocular/methods , Glaucoma/physiopathology , Ocular Hypertension/physiopathology , Tonometry, Ocular/statistics & numerical data , Comparative Study , Glaucoma/diagnosis , Glaucoma/epidemiology , Ocular Hypertension/diagnosis , Ocular Hypertension/epidemiology , Cross-Sectional Studies , Probability , Cornea/physiology , Observational Study , Intraocular Pressure/physiology
19.
Korean Journal of Ophthalmology ; : 225-233, 2016.
Article in English | WPRIM | ID: wpr-188293

ABSTRACT

PURPOSE: We explored the performance of and pressure elevation caused by small-diameter microtubes used to reduce overfiltration. METHODS: Using a syringe pump-driven constant-flow setting (2 µL/min), pressures were measured for polytetrafluoroethylene (PTFE) microtubes 5 mm in length with inner diameters of 51, 64, and 76 µm and for polyether block amide (PEBAX) microtubes with an inner diameter of 76 µm. Experiments (using microtubes only) were initially performed in air, water, and enucleated pig eyes and were repeated under the same conditions using intraluminal 9/0 nylon stents. RESULTS: The pressures measured in air in 51-, 64-, and 76-µm-diameter PTFE microtubes differed significantly (22.1, 16.9, and 12.2 mmHg, respectively; p < 0.001), and that of the 76-µm-diameter PEBAX microtube was 15.8 mmHg (p < 0.001 compared to the 12.2 mmHg of the 76-µm-diameter PTFE microtube). The pressures measured in water also differed significantly among the three microtubes at 3.9, 3.0, and 1.4 mmHg, respectively, while that in the PEBAX microtube was 2.6 mmHg (all p < 0.001). Using the intraluminal stent, the pressure in water of the three different PTFE microtubes increased to 22.6, 18.0, and 4.1 mmHg, respectively, and that in the PEBAX microtube increased to 10.5 mmHg (all p < 0.001). Similar trends were evident when measurements were performed in pig eyes. CONCLUSIONS: Although microtubes of smaller diameter experienced higher pressure in air, reduction of the inner diameter to 51 µm did not adequately increase the pressure attained in water or pig eyes. Insertion of an intraluminal stent effectively elevated the latter pressures. PEBAX microtubes created higher pressures than did PTFE microtubes.


Subject(s)
Animals , Disease Models, Animal , Glaucoma/physiopathology , Glaucoma Drainage Implants , Intraocular Pressure/physiology , Ophthalmologic Surgical Procedures/instrumentation , Polytetrafluoroethylene , Prosthesis Design , Swine